Air dehumidifiers of the MSHA(C) series are equipped with three* stages of air filtration. They feature low maintenance costs and energy-saving capabilities. These dehumidifiers are fully automated and easy to operate. The ducted design of these dehumidifiers allows for concealed installation.
* 3-stage filtration from 60 to 140 models
The heat exchange coil is made of high-efficiency copper tubes with blue hydrophilic aluminum fins. The condensate tray is made of SUS304. The forced filter replacement function further improves air cleaning quality and product lifespan.

The electronic expansion valve (EEV) is a modern component of the refrigeration system that precisely regulates the flow of refrigerant into the evaporator using an electronic controller and a small motor based on the current system parameters, such as temperature and pressure. It provides higher energy efficiency and performance compared to traditional mechanical valves, adapting to load changes, making it indispensable for modern heating, ventilation, and air conditioning systems.
Compressor with permanent magnet inverter motor
|
Inverter fan motor
|
Intelligent control
|
Mix fresh air and return air, and process the mixed air to maintain freshness and dryness of the indoor air.
Intelligent introduction of external air to maintain the freshness of indoor air. Suitable for indoor humidity < 60%RH.
Energy-saving dehumidification mode, lower energy consumption for continuous operation. Suitable for indoor humidity <75%RH.

| Technical specifications | Unit | MSHA(C)-60IX | MSHA(C)-100IX | MSHA(C)-140IX | MSHA(C)-180IX |
| Testing conditions | 30°C, 80% | ||||
| Dehumidification | l/day | 60 | 100 | 140 | 180 |
| Fan type | Stepless speed control (0-10 V) | ||||
| Total air supply volume | m³/h | 650-780 | 1000-1200 | 1200-1350 | 1700-2200 |
| Residual pressure of supply air | Pa | 100 | 100 | 100 | 200 |
| Return air volume | m³/h | 780-550 | 680-800 | 750-850 | 1600-2200 |
| Fresh air volume | m³/h | 0-230 | 0-400 | 0-500 | 0-600 |
| Power/Current | W/A | 950/4.3 | 1450/6.5 | 1680/7.6 | 1830/3.8 |
| Voltage/Frequency | V/Hz | 220/50 | 220/50 | 220/50 | 380/50 |
| Control method | Fully touch-sensitive LCD display | ||||
| Electricity/Dust protection class (IP) | Class I/IPX3 | ||||
| Noise | dB(A) | <45 | <48 | ||
| Compressor | Panasonic/Embraco, inverter, R32 | ||||
| Gas charge | g | 600 | 700 | 750 | 1600 |
| Return air sensor | Multifunctional 5-in-1 | ||||
| New air valve | Built-in | ||||
| Heat exchanger | Hydrophilic aluminum fins with copper tubes | ||||
| Drain pan pipe diameter | Ø20 | Ø32 | |||
| Filtration (standard) | Initial/Medium/High efficiency | Initial/Medium | |||
| Cleaning (standard) | Sterilization with negative ions/UV radiation | ||||
| Size | mm | 1090×689×310 | 1150×819×600 | ||
| Net weight | kg | 70 | 70 | 73 | 110 |
| Fresh air inlet | mm | Ø150 | 269×264 | ||
| Return air inlet | mm | Ø200 | 300×350 | ||
| Air discharge inlet | mm | Ø200 | 350×350 | ||
| Technical specifications | Unit | MSHA(C)-250IX | MSHA(C)-380IX | MSHA(C)-500IX |
| Testing conditions | 30°C, 80% | |||
| Dehumidification | l/day | 250 | 380 | 500 |
| Fan type | Stepless speed control (0-10 V) | |||
| Total air supply volume | m³/h | 1900-2700 | 3500-3850 | 4800-5300 |
| Residual pressure of supply air | Pa | 200 | 250 | 250 |
| Return air volume | m³/h | 2100-2700 | 2750-3850 | 3800-5300 |
| Fresh air volume | m³/h | 0-800 | 0-1000 | 0-1500 |
| Power/Current | W/A | 4200/6.4 | 6246/11.6 | 9224/14 |
| Voltage/Frequency | V/Hz | 380/50 | 380/50 | 380/50 |
| Control method | Fully touch-sensitive LCD display | |||
| Electricity/Dust protection class (IP) | Class I/IPX3 | Class I/IPX4 | ||
| Noise | dB(A) | <48 | <50 | <55 |
| Compressor | ||||
| Gas charge | g | 1800 | 2500 | 2800 |
| Return air sensor | Multifunctional 5-in-1 | |||
| New air valve | Built-in | |||
| Heat exchanger | Hydrophilic aluminum fins with copper tubes | |||
| Drain pan pipe diameter | Ø32 | |||
| Filtration (standard) | Initial/Medium | |||
| Cleaning (standard) | Sterilization with negative ions/UV radiation | |||
| Size | mm | 1150×819×600 | 1350×1116×720 | 1350×1116×720 |
| Net weight | kg | 121 | 199 | 202 |
| Fresh air inlet | mm | 269×264 | 373×228 | 373×228 |
| Return air inlet | mm | 300×350 | 450×430 | 450×430 |
| Air discharge inlet | mm | 350×350 | 818×313 | 818×313 |
MODULAR
| Technical specifications | Unit | MSHA(C)-60IX | MSHA(C)-100IX | MSHA(C)-140IX |
| Testing conditions | 30°C, 80% | |||
| Dehumidification | l/day | 60 | 100 | 140 |
| Fan type | Stepless speed control (0-10 V) | |||
| Total air supply volume | m³/h | 650-780 | 1000-1200 | 1200-1350 |
| Residual pressure of supply air | Pa | 100 | 100 | 100 |
| Return air volume | m³/h | 780-550 | 680-800 | 750-850 |
| Fresh air volume | m³/h | 0-230 | 0-400 | 0-500 |
| Power/Current | W/A | 950/4.3 | 1450/6.5 | 1680/7.6 |
| Voltage/Frequency | V/Hz | 220/50 | 220/50 | 220/50 |
| Control method | Fully touch-sensitive LCD display | |||
| Electricity/Dust protection class (IP) | Class I/IPX3 | |||
| Noise | dB(A) | <45 | <45 | <45 |
| Compressor | Panasonic/Embraco, inverter, R32 | |||
| Gas charge | g | 600 | 700 | 750 |
| Return air sensor | Multifunctional 5-in-1 | |||
| New air valve | Built-in | |||
| Heat exchanger | Hydrophilic aluminum fins with copper tubes | |||
| Drain pan pipe diameter | Ø20 | Ø20 | Ø20 | |
| Filtration (standard) | Initial/Medium/High efficiency | |||
| Cleaning (standard) | Sterilization with negative ions/UV radiation | |||
| Size | mm | 1160×590×325 | 1200×640×370 | |
| Net weight | kg | 70 | 70 | 73 |
| Fresh air inlet | mm | Ø150 | Ø150 | Ø150 |
| Return air inlet | mm | Ø200 | Ø200 | Ø200 |
| Air discharge inlet | mm | Ø200 | Ø200 | Ø200 |